EPA 608 Type I · Section 608 Regulations · Hard

Why isn't a ductless mini-split that holds only 3 lbs of refrigerant a small appliance?

Answer: A. Its refrigerant circuit is completed in the field.

  1. AIts refrigerant circuit is completed in the field.✓ Correct
  2. BIts charge is over the small appliance limit.
  3. CMini-splits use refrigerants exempt from Section 608.
  4. DIt has a variable-speed compressor.

Why A is right

The small appliance definition requires the unit to be fully manufactured, charged and hermetically sealed in a factory. A mini-split's line set is connected on site, so it is not a small appliance however small its charge. Servicing it calls for Type II or Universal.